{"id":1382,"date":"2024-10-09T07:12:12","date_gmt":"2024-10-09T07:12:12","guid":{"rendered":"https:\/\/www.hng-ua.com\/?page_id=1382"},"modified":"2024-11-25T14:24:07","modified_gmt":"2024-11-25T14:24:07","slug":"capacitive-equipment","status":"publish","type":"page","link":"https:\/\/www.hng-ua.com\/en\/capacitive-equipment\/","title":{"rendered":"Capacitive equipment"},"content":{"rendered":"\n<h4>Capacitive equipment of our own production:<\/h4>\n\n\n\n<figure class=\"wp-container-2 wp-block-gallery-1 wp-block-gallery has-nested-images columns-2 is-cropped\">\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.hng-ua.com\/wp-content\/uploads\/2024\/11\/IMG_8372-scaled.jpg\"><img loading=\"lazy\" width=\"1024\" height=\"699\" data-id=\"1948\"  src=\"https:\/\/www.hng-ua.com\/wp-content\/uploads\/2024\/11\/IMG_8372-1024x699.jpg\" alt=\"\" class=\"wp-image-1948\" srcset=\"https:\/\/www.hng-ua.com\/wp-content\/uploads\/2024\/11\/IMG_8372-1024x699.jpg 1024w, https:\/\/www.hng-ua.com\/wp-content\/uploads\/2024\/11\/IMG_8372-300x205.jpg 300w, https:\/\/www.hng-ua.com\/wp-content\/uploads\/2024\/11\/IMG_8372-768x525.jpg 768w, https:\/\/www.hng-ua.com\/wp-content\/uploads\/2024\/11\/IMG_8372-1536x1049.jpg 1536w, https:\/\/www.hng-ua.com\/wp-content\/uploads\/2024\/11\/IMG_8372-2048x1399.jpg 2048w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.hng-ua.com\/wp-content\/uploads\/2024\/11\/0-02-05-bd69b4cce9a45621b68da4a7de6f3363d30667bd81b4189ff387fe12ce3aadd5_b2c82152e0bda9bb.jpg\"><img loading=\"lazy\" width=\"1024\" height=\"618\" data-id=\"1933\"  src=\"https:\/\/www.hng-ua.com\/wp-content\/uploads\/2024\/11\/0-02-05-bd69b4cce9a45621b68da4a7de6f3363d30667bd81b4189ff387fe12ce3aadd5_b2c82152e0bda9bb-1024x618.jpg\" alt=\"\" class=\"wp-image-1933\" srcset=\"https:\/\/www.hng-ua.com\/wp-content\/uploads\/2024\/11\/0-02-05-bd69b4cce9a45621b68da4a7de6f3363d30667bd81b4189ff387fe12ce3aadd5_b2c82152e0bda9bb-1024x618.jpg 1024w, https:\/\/www.hng-ua.com\/wp-content\/uploads\/2024\/11\/0-02-05-bd69b4cce9a45621b68da4a7de6f3363d30667bd81b4189ff387fe12ce3aadd5_b2c82152e0bda9bb-300x181.jpg 300w, https:\/\/www.hng-ua.com\/wp-content\/uploads\/2024\/11\/0-02-05-bd69b4cce9a45621b68da4a7de6f3363d30667bd81b4189ff387fe12ce3aadd5_b2c82152e0bda9bb-768x464.jpg 768w, https:\/\/www.hng-ua.com\/wp-content\/uploads\/2024\/11\/0-02-05-bd69b4cce9a45621b68da4a7de6f3363d30667bd81b4189ff387fe12ce3aadd5_b2c82152e0bda9bb-1536x927.jpg 1536w, https:\/\/www.hng-ua.com\/wp-content\/uploads\/2024\/11\/0-02-05-bd69b4cce9a45621b68da4a7de6f3363d30667bd81b4189ff387fe12ce3aadd5_b2c82152e0bda9bb.jpg 1600w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/www.hng-ua.com\/wp-content\/uploads\/2024\/11\/\u0454\u043c\u043d\u0456\u0441\u0442\u044c-\u043f\u0456\u0434-\u0433\u0430\u0437\u043e\u0432\u0438\u0439-\u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442-25\u043c3.jpg\"><img loading=\"lazy\" width=\"1004\" height=\"640\" data-id=\"1963\"  src=\"https:\/\/www.hng-ua.com\/wp-content\/uploads\/2024\/11\/\u0454\u043c\u043d\u0456\u0441\u0442\u044c-\u043f\u0456\u0434-\u0433\u0430\u0437\u043e\u0432\u0438\u0439-\u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442-25\u043c3.jpg\" alt=\"\u0415\u043c\u043a\u043e\u0441\u0442\u044c \u043f\u043e\u0434 \u0433\u0430\u0437\u043e\u0432\u044b\u0439 \u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442 25\u043c3\" class=\"wp-image-1963\" srcset=\"https:\/\/www.hng-ua.com\/wp-content\/uploads\/2024\/11\/\u0454\u043c\u043d\u0456\u0441\u0442\u044c-\u043f\u0456\u0434-\u0433\u0430\u0437\u043e\u0432\u0438\u0439-\u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442-25\u043c3.jpg 1004w, https:\/\/www.hng-ua.com\/wp-content\/uploads\/2024\/11\/\u0454\u043c\u043d\u0456\u0441\u0442\u044c-\u043f\u0456\u0434-\u0433\u0430\u0437\u043e\u0432\u0438\u0439-\u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442-25\u043c3-300x191.jpg 300w, https:\/\/www.hng-ua.com\/wp-content\/uploads\/2024\/11\/\u0454\u043c\u043d\u0456\u0441\u0442\u044c-\u043f\u0456\u0434-\u0433\u0430\u0437\u043e\u0432\u0438\u0439-\u043a\u043e\u043d\u0434\u0435\u043d\u0441\u0430\u0442-25\u043c3-768x490.jpg 768w\" sizes=\"(max-width: 1004px) 100vw, 1004px\" \/><\/a><figcaption>Capacity for gas condensate 25 m3<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.hng-ua.com\/wp-content\/uploads\/2024\/11\/IMG_7798-scaled.jpg\"><img loading=\"lazy\" width=\"1024\" height=\"768\" data-id=\"1942\"  src=\"https:\/\/www.hng-ua.com\/wp-content\/uploads\/2024\/11\/IMG_7798-1024x768.jpg\" alt=\"\" class=\"wp-image-1942\" srcset=\"https:\/\/www.hng-ua.com\/wp-content\/uploads\/2024\/11\/IMG_7798-1024x768.jpg 1024w, https:\/\/www.hng-ua.com\/wp-content\/uploads\/2024\/11\/IMG_7798-300x225.jpg 300w, https:\/\/www.hng-ua.com\/wp-content\/uploads\/2024\/11\/IMG_7798-768x576.jpg 768w, https:\/\/www.hng-ua.com\/wp-content\/uploads\/2024\/11\/IMG_7798-1536x1152.jpg 1536w, https:\/\/www.hng-ua.com\/wp-content\/uploads\/2024\/11\/IMG_7798-2048x1536.jpg 2048w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.hng-ua.com\/wp-content\/uploads\/2024\/11\/\u0440\u0435\u0437\u0435\u0440\u0432\u0443\u0430\u0440-83\u043c3-\u041a\u0435\u0440\u043d\u0435\u043b-\u043a\u043e\u043f\u0456\u044f-scaled.jpg\"><img loading=\"lazy\" width=\"1024\" height=\"768\" data-id=\"2059\"  src=\"https:\/\/www.hng-ua.com\/wp-content\/uploads\/2024\/11\/\u0440\u0435\u0437\u0435\u0440\u0432\u0443\u0430\u0440-83\u043c3-\u041a\u0435\u0440\u043d\u0435\u043b-\u043a\u043e\u043f\u0456\u044f-1024x768.jpg\" alt=\"\" class=\"wp-image-2059\" srcset=\"https:\/\/www.hng-ua.com\/wp-content\/uploads\/2024\/11\/\u0440\u0435\u0437\u0435\u0440\u0432\u0443\u0430\u0440-83\u043c3-\u041a\u0435\u0440\u043d\u0435\u043b-\u043a\u043e\u043f\u0456\u044f-1024x768.jpg 1024w, https:\/\/www.hng-ua.com\/wp-content\/uploads\/2024\/11\/\u0440\u0435\u0437\u0435\u0440\u0432\u0443\u0430\u0440-83\u043c3-\u041a\u0435\u0440\u043d\u0435\u043b-\u043a\u043e\u043f\u0456\u044f-300x225.jpg 300w, https:\/\/www.hng-ua.com\/wp-content\/uploads\/2024\/11\/\u0440\u0435\u0437\u0435\u0440\u0432\u0443\u0430\u0440-83\u043c3-\u041a\u0435\u0440\u043d\u0435\u043b-\u043a\u043e\u043f\u0456\u044f-768x576.jpg 768w, https:\/\/www.hng-ua.com\/wp-content\/uploads\/2024\/11\/\u0440\u0435\u0437\u0435\u0440\u0432\u0443\u0430\u0440-83\u043c3-\u041a\u0435\u0440\u043d\u0435\u043b-\u043a\u043e\u043f\u0456\u044f-1536x1152.jpg 1536w, https:\/\/www.hng-ua.com\/wp-content\/uploads\/2024\/11\/\u0440\u0435\u0437\u0435\u0440\u0432\u0443\u0430\u0440-83\u043c3-\u041a\u0435\u0440\u043d\u0435\u043b-\u043a\u043e\u043f\u0456\u044f-2048x1536.jpg 2048w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.hng-ua.com\/wp-content\/uploads\/2024\/11\/\u0415\u043c\u043a\u043e\u0441\u0442\u044c-15\u043c3-1-scaled.jpg\"><img loading=\"lazy\" width=\"1024\" height=\"768\" data-id=\"1954\"  src=\"https:\/\/www.hng-ua.com\/wp-content\/uploads\/2024\/11\/\u0415\u043c\u043a\u043e\u0441\u0442\u044c-15\u043c3-1-1024x768.jpg\" alt=\"\u0415\u043c\u043a\u043e\u0441\u0442\u044c 15\u043c3 \" class=\"wp-image-1954\" srcset=\"https:\/\/www.hng-ua.com\/wp-content\/uploads\/2024\/11\/\u0415\u043c\u043a\u043e\u0441\u0442\u044c-15\u043c3-1-1024x768.jpg 1024w, https:\/\/www.hng-ua.com\/wp-content\/uploads\/2024\/11\/\u0415\u043c\u043a\u043e\u0441\u0442\u044c-15\u043c3-1-300x225.jpg 300w, https:\/\/www.hng-ua.com\/wp-content\/uploads\/2024\/11\/\u0415\u043c\u043a\u043e\u0441\u0442\u044c-15\u043c3-1-768x576.jpg 768w, https:\/\/www.hng-ua.com\/wp-content\/uploads\/2024\/11\/\u0415\u043c\u043a\u043e\u0441\u0442\u044c-15\u043c3-1-1536x1152.jpg 1536w, https:\/\/www.hng-ua.com\/wp-content\/uploads\/2024\/11\/\u0415\u043c\u043a\u043e\u0441\u0442\u044c-15\u043c3-1-2048x1536.jpg 2048w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption>Capacity V=15m3 P=0.6MPa<\/figcaption><\/figure>\n<\/figure>\n\n\n<p><strong>Designing and manufacturing of tank equipment according to standard and non-standard designs is one of the main activities of the production enterprise &#8220;Khimmashneftegaz&#8221;.<\/strong><\/p>\n<p>Capacitive equipment is designed for receiving, storing, processing and dispensing aggressive, toxic and non-toxic, explosive and non-explosive and other liquid and gaseous products for use in the chemical, petrochemical, food and other industries.<\/p>\n<p>The devices can be of horizontal or vertical type and are made of carbon and corrosion-resistant steels.<\/p>\n<p style=\"text-align: center;\"><span style=\"text-decoration: underline;\"><strong>&#8220;Khimmashneftegaz&#8221; LLC manufactures various types of tank equipment:<\/strong><\/span><\/p>\n<div class=\"table-responsive\">\n<table class=\"table table-bordered\">\n<tbody>\n<tr>\n<td style=\"text-align: center;\" rowspan=\"2\"><strong>Name of the device<\/strong><\/td>\n<td style=\"text-align: center;\" rowspan=\"2\"><strong>Sketch<\/strong><\/td>\n<td style=\"text-align: center;\" colspan=\"2\"><strong>Assignment parameters<\/strong><\/td>\n<td style=\"text-align: center;\" rowspan=\"2\"><strong>Appointment<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\"><strong>Nominal volume, m3<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>Conditional pressure, MPa<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>Horizontal with elliptical bottoms, GEE<\/strong><\/td>\n<td><img src=\"https:\/\/www.hng-ua.com\/wp-content\/uploads\/2018\/08\/01.jpg\" alt=\"\u0415\u041c\u041a\u041e\u0421\u0422\u041d\u041e\u0415 \u041e\u0411\u041e\u0420\u0423\u0414\u041e\u0412\u0410\u041d\u0418\u0415\"><\/td>\n<td><span style=\"font-weight: 400;\">6,3; 10; 16; 25; 40; 50; 63; 80; 100<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0,6; 1,0; 1,6<\/span><\/td>\n<td>Designed for receiving, storing and dispensing liquid and gaseous media (including hazardous, explosive and fire hazardous substances).<\/td>\n<\/tr>\n<tr>\n<td><strong>Horizontal with elliptical bottoms, with a tube bundle, GEE<\/strong><\/td>\n<td><img loading=\"lazy\" class=\"alignnone size-full wp-image-162\" src=\"https:\/\/www.hng-ua.com\/wp-content\/uploads\/2018\/08\/02.jpg\" alt=\"\u0415\u043c\u043a\u043e\u0441\u0442\u043d\u043e\u0435 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435\" width=\"168\" height=\"76\"><\/td>\n<td><span style=\"font-weight: 400;\">6,3; 10; 16; 25; 40; 50; 63<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0,6<\/span><\/td>\n<td>They are designed for receiving, storing and dispensing liquid and gaseous media (including hazardous, explosive and fire hazardous substances) if such media require maintaining a specified temperature regime during storage. The pressure of the coolant in the pipe bundle is not more than 0.6 MPa.<\/td>\n<\/tr>\n<tr>\n<td><strong>Vertical with elliptical bottoms, VEE<\/strong><\/td>\n<td><img loading=\"lazy\" class=\"alignnone size-full wp-image-171\" src=\"https:\/\/www.hng-ua.com\/wp-content\/uploads\/2018\/08\/12.jpg\" alt=\"\" width=\"169\" height=\"95\"><\/td>\n<td><span style=\"font-weight: 400;\">1; 2; 3,2; 5; 6,3; 10; 16; 25; 32; 40; 50; 63<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0,6; 1,0; 1,6<\/span><\/td>\n<td>They are designed for receiving, storing and dispensing liquid and gaseous media (including hazardous, explosive and fire hazardous substances). If necessary, they can be equipped with an internal coil to maintain a given temperature regime in the device. The pressure of the coolant in the coil is not more than 0.6 MPa.<\/td>\n<\/tr>\n<tr>\n<td><strong>Vertical with elliptical bottoms, with jacket, VEE<\/strong><\/td>\n<td><img loading=\"lazy\" class=\"alignnone size-full wp-image-173\" src=\"https:\/\/www.hng-ua.com\/wp-content\/uploads\/2018\/08\/13.jpg\" alt=\"\" width=\"169\" height=\"95\"><\/td>\n<td><span style=\"font-weight: 400;\">1; 2; 3,2; 5; 6,3; 10<\/span><\/td>\n<td><span style=\"font-weight: 400;\">1,0<\/span><\/td>\n<td>Designed for receiving, storing and dispensing liquid and gaseous media (including hazardous, explosive and fire hazardous substances) if such media require maintaining a specified temperature regime during storage. The pressure of the coolant in the jacket is slightly more than 0.6 MPa.<\/td>\n<\/tr>\n<tr>\n<td><strong>Vertical with lower conical and upper elliptical bottoms, VKE<\/strong><\/td>\n<td><img loading=\"lazy\" class=\"alignnone size-full wp-image-174\" src=\"https:\/\/www.hng-ua.com\/wp-content\/uploads\/2018\/08\/14.jpg\" alt=\"\" width=\"169\" height=\"130\"><\/td>\n<td><span style=\"font-weight: 400;\">1; 2; 3,2; 5; 6,3; 10<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0,6<\/span><\/td>\n<td>Designed for receiving, storing and dispensing liquid and gaseous media (including hazardous, explosive and fire hazardous substances), high viscosity, as well as media containing precipitated substances.<\/td>\n<\/tr>\n<tr>\n<td><strong>Vertical with lower conical and upper elliptical bottoms, with jacket, VKE<\/strong><\/td>\n<td><img loading=\"lazy\" class=\"alignnone size-full wp-image-175\" src=\"https:\/\/www.hng-ua.com\/wp-content\/uploads\/2018\/08\/15.jpg\" alt=\"\" width=\"169\" height=\"130\"><\/td>\n<td><span style=\"font-weight: 400;\">1; 2; 3,2; 5; 6,3; 10<\/span><\/td>\n<td><span style=\"font-weight: 400;\">1,0<\/span><\/td>\n<td>Designed for receiving, storing and dispensing liquid and gaseous media (including hazardous, explosive and fire hazardous substances), high viscosity and media containing precipitating substances, if such media require maintaining a specified temperature regime during storage. The pressure of the coolant in the jacket is slightly more than 0.6 MPa. For devices with a volume of 3.2 m3, the pressure of the coolant in the jacket at a temperature above 200\u00b0C is not more than 0.55 MPa.<\/td>\n<\/tr>\n<tr>\n<td><strong>Vertical tanks with conical bottom and elliptical lid, VKE<\/strong><\/td>\n<td><img loading=\"lazy\" class=\"alignnone size-full wp-image-176\" src=\"https:\/\/www.hng-ua.com\/wp-content\/uploads\/2018\/08\/16.jpg\" alt=\"\" width=\"104\" height=\"151\"><\/td>\n<td><span style=\"font-weight: 400;\">1; 2; 3,2<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0,6<\/span><\/td>\n<td>Designed for receiving, storing and dispensing liquid and gaseous media (including hazardous, explosive and fire hazardous substances), high viscosity and media containing precipitated substances, operation with which requires frequent cleaning of internal surfaces.<\/td>\n<\/tr>\n<tr>\n<td><strong>Vertical with conical bottom and elliptical lid, with jacket, VKE<\/strong><\/td>\n<td><img loading=\"lazy\" class=\"alignnone size-full wp-image-177\" src=\"https:\/\/www.hng-ua.com\/wp-content\/uploads\/2018\/08\/17.jpg\" alt=\"\" width=\"104\" height=\"151\"><\/td>\n<td><span style=\"font-weight: 400;\">1; 2; 3,2<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0,6<\/span><\/td>\n<td>Designed for receiving, storing and dispensing liquid and gaseous media (including hazardous, explosive and fire hazardous substances), high viscosity and media containing precipitated substances, operation with which requires frequent cleaning of internal surfaces, if such media require maintaining the specified temperature regime.<\/td>\n<\/tr>\n<tr>\n<td><strong>Horizontal with conical bottoms, GKK<\/strong><\/td>\n<td><img loading=\"lazy\" class=\"alignnone size-full wp-image-178\" src=\"https:\/\/www.hng-ua.com\/wp-content\/uploads\/2018\/08\/18.jpg\" alt=\"\" width=\"165\" height=\"70\"><\/td>\n<td><span style=\"font-weight: 400;\">10; 16; 25; 40; 50; 63; 80; 100<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0<\/span><\/td>\n<td>They are designed for receiving, storing and dispensing liquid and gaseous media (including hazardous, explosive and fire hazardous substances) at a pressure in the device not exceeding the permissible pressure and a temperature not exceeding 100\u00b0C.<\/td>\n<\/tr>\n<tr>\n<td><strong>Vertical with lower conical and upper flat bottoms, with or without coil, KP<\/strong><\/td>\n<td><img loading=\"lazy\" class=\"alignnone size-full wp-image-179\" src=\"https:\/\/www.hng-ua.com\/wp-content\/uploads\/2018\/08\/19.jpg\" alt=\"\" width=\"104\" height=\"163\"><\/td>\n<td><span style=\"font-weight: 400;\">10; 16; 25<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0<\/span><\/td>\n<td>They are designed for receiving, storing and dispensing liquid and gaseous media (including hazardous substances of hazard classes 3 and 4 according to GOST 12.1.007-76), high viscosity and media containing precipitated substances at atmospheric pressure. If it is necessary to maintain a given temperature regime in the device, the devices can be equipped with an internal coil. The pressure of the coolant in the coil is not more than 0.6 MPa.<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Vertical flat-bottomed (or with lower flat and upper conical bottoms), with or without coil, VPD (VPK)<\/strong><\/p>\n<\/td>\n<td><img loading=\"lazy\" class=\"alignnone size-full wp-image-180\" src=\"https:\/\/www.hng-ua.com\/wp-content\/uploads\/2018\/08\/20.jpg\" alt=\"\" width=\"173\" height=\"107\"><\/td>\n<td><span style=\"font-weight: 400;\">10; 16; 25; 32; 40; 50; 63<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0<\/span><\/td>\n<td>They are designed for receiving, storing and dispensing liquid and gaseous media (including hazardous substances of hazard classes 3 and 4 according to GOST 12.1.007-76) at atmospheric pressure. If it is necessary to maintain a given temperature regime in the device, the devices can be equipped with an internal coil. The pressure of the coolant in the coil is not more than 0.6 MPa.<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Vertical with elliptical bottom and lid, VEE<\/strong><\/p>\n<\/td>\n<td><img loading=\"lazy\" class=\"alignnone size-full wp-image-181\" src=\"https:\/\/www.hng-ua.com\/wp-content\/uploads\/2018\/08\/21.jpg\" alt=\"\" width=\"165\" height=\"92\"><\/td>\n<td><span style=\"font-weight: 400;\">3,2; 6,3; 10; 16; 25; 32; 40; 50; 63<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0<\/span><\/td>\n<td>Designed for receiving, storing and dispensing liquid and gaseous media (including hazardous, explosive and fire hazardous substances).<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Horizontal with elliptical bottoms, GEE<\/strong><\/p>\n<\/td>\n<td><img loading=\"lazy\" class=\"alignnone size-full wp-image-182\" src=\"https:\/\/www.hng-ua.com\/wp-content\/uploads\/2018\/08\/22.jpg\" alt=\"\" width=\"182\" height=\"81\"><\/td>\n<td><span style=\"font-weight: 400;\">6,3; 10; 16; 25; 40; 50; 63; 80; 100<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0,6<\/span><\/td>\n<td>Designed for receiving, storing and dispensing liquid and gaseous media (including hazardous, explosive and fire hazardous substances).<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Vertical with lower flat and upper conical bottoms, MIC<\/strong><\/p>\n<\/td>\n<td><img loading=\"lazy\" class=\"alignnone size-full wp-image-184\" src=\"https:\/\/www.hng-ua.com\/wp-content\/uploads\/2018\/08\/23.jpg\" alt=\"\" width=\"81\" height=\"93\"><\/td>\n<td><span style=\"font-weight: 400;\">10; 16; 25; 32; 40; 50; 63<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0<\/span><\/td>\n<td>They are designed for receiving, storing and dispensing at atmospheric pressure liquid media that are harmless, fireproof and explosion-proof.<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Horizontal with elliptical bottoms, GEE<\/strong><\/p>\n<\/td>\n<td><img loading=\"lazy\" class=\"alignnone size-full wp-image-185\" src=\"https:\/\/www.hng-ua.com\/wp-content\/uploads\/2018\/08\/24.jpg\" alt=\"\" width=\"177\" height=\"79\"><\/td>\n<td><span style=\"font-weight: 400;\">2,5; 4; 6,3; 10; 16; 25; 40; 50; 63; 80; 100<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0,07; 0,25<\/span><\/td>\n<td>\n<p>They are designed for receiving, storing and dispensing liquid and gaseous media with a density of no more than 1600 <sup>kg\/cm3<\/sup> at an operating pressure not exceeding the values given in the technical specification and a working medium temperature from -40 to +70\u00b0C.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Horizontal with elliptical bottoms, with a pipe bundle, GEE<\/strong><\/p>\n<\/td>\n<td><img loading=\"lazy\" class=\"alignnone size-full wp-image-186\" src=\"https:\/\/www.hng-ua.com\/wp-content\/uploads\/2018\/08\/25.jpg\" alt=\"\" width=\"177\" height=\"79\"><\/td>\n<td><span style=\"font-weight: 400;\">6,3; 10; 16; 25; 40; 50; 63<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0,07<\/span><\/td>\n<td>They are designed for receiving, storing and dispensing liquid and gaseous media (including hazardous, explosive and fire hazardous substances) that require maintaining a specified temperature regime during storage. The pressure of the coolant in the pipe bundle is not more than 0.3 MPa.<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Vertical with elliptical bottoms, VEE<\/strong><\/p>\n<\/td>\n<td><img loading=\"lazy\" class=\"alignnone size-full wp-image-187\" src=\"https:\/\/www.hng-ua.com\/wp-content\/uploads\/2018\/08\/26.jpg\" alt=\"\" width=\"104\" height=\"124\"><\/td>\n<td><span style=\"font-weight: 400;\">1; 1,6; 2,5; 4; 6,3; 10; 16; 25<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0,07; 0,25<\/span><\/td>\n<td>\n<p>They are designed for receiving, storing and dispensing liquid and gaseous media with a density of no more than 1600 <sup>kg\/cm3<\/sup> at an operating pressure not exceeding the values given in the technical specifications and a working medium temperature from -40 to +70\u00b0C.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Vertical with flat bottoms, VPP<\/strong><\/p>\n<\/td>\n<td><img loading=\"lazy\" class=\"alignnone size-full wp-image-188\" src=\"https:\/\/www.hng-ua.com\/wp-content\/uploads\/2018\/08\/29.jpg\" alt=\"\" width=\"104\" height=\"124\"><\/td>\n<td><span style=\"font-weight: 400;\">1; 1,6; 2,5; 4; 6,3; 10; 16; 25; 40; 50<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0<\/span><\/td>\n<td>Designed for receiving, storing and dispensing liquid explosive and fire hazardous media at atmospheric pressure.<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Horizontal heat-treated, GEE<\/strong><\/p>\n<\/td>\n<td><img loading=\"lazy\" class=\"alignnone size-full wp-image-189\" src=\"https:\/\/www.hng-ua.com\/wp-content\/uploads\/2018\/08\/30.jpg\" alt=\"\" width=\"205\" height=\"115\"><\/td>\n<td><span style=\"font-weight: 400;\">10; 16; 25; 40; 63; 100<\/span><\/td>\n<td><span style=\"font-weight: 400;\">1,0<\/span><\/td>\n<td rowspan=\"2\">They are intended for receiving, storing and dispensing liquid and gaseous media (including harmful, explosive and fire hazardous substances) at the pressure specified in the technical characteristics and at a temperature not exceeding 200\u00b0C under conditions of statistical and low-cycle loads with the number of load cycles for the entire service life not exceeding 1000 when installed in areas with seismicity not exceeding 6 points. If it is necessary to maintain a given temperature regime in the device, the devices can be equipped with external heat exchange devices. The coolant pressure is not more than 1.6 MPa.<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Vertical heat-treated, VEE<\/strong><\/p>\n<\/td>\n<td><img loading=\"lazy\" class=\"alignnone size-full wp-image-190\" src=\"https:\/\/www.hng-ua.com\/wp-content\/uploads\/2018\/08\/31.jpg\" alt=\"\" width=\"186\" height=\"146\"><\/td>\n<td><span style=\"font-weight: 400;\">1; 1,6; 2,5; 4; 6,3; 10; 16; 25<\/span><\/td>\n<td><span style=\"font-weight: 400;\">1,0<\/span><\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Horizontal cylindrical, GEE<\/strong><\/p>\n<\/td>\n<td><img loading=\"lazy\" class=\"alignnone size-full wp-image-191\" src=\"https:\/\/www.hng-ua.com\/wp-content\/uploads\/2018\/08\/32.jpg\" alt=\"\" width=\"168\" height=\"75\"><\/td>\n<td><span style=\"font-weight: 400;\">4; 8; 10; 16; 20; 25; 32; 50; 80; 100<\/span><\/td>\n<td><span style=\"font-weight: 400;\">1,0; 1,6; 2,5<\/span><\/td>\n<td rowspan=\"3\">\n<p>They are designed for receiving, storing and dispensing liquid and gaseous media (fire hazardous, explosive &#8211; explosion category T1, T2, T3 according to GOST 12.1.011-78, harmful &#8211; hazard classes 3 and 4 according to GOST 12.1. 007-76), with a density of no more than 1000 <sup>kg\/m3<\/sup> at a pressure in the device not exceeding the permissible pressure and a temperature from -6\u00b0C to +200\u00b0C under static and low-cycle loads with a number of load cycles for the entire service life not exceeding 1000 when installed in areas with a seismicity of no more than 7 points. The devices are equipped with fittings. If it is necessary to maintain a given temperature regime in the device, the devices can be equipped with external or internal coils on request. The pressure of the coolant in the external coils is not more than 1.6 MPa, and in the internal coils &#8211; not more than the conditional pressure of the apparatus, but not more than 1.6 MPa.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Vertical cylindrical vials for liquid media, VEE<\/strong><\/p>\n<\/td>\n<td><img loading=\"lazy\" class=\"alignnone size-full wp-image-192\" src=\"https:\/\/www.hng-ua.com\/wp-content\/uploads\/2018\/08\/33.jpg\" alt=\"\" width=\"107\" height=\"153\"><\/td>\n<td><span style=\"font-weight: 400;\">4; 6,3; 10; 16; 25; 32; 50; 80; 100<\/span><\/td>\n<td><span style=\"font-weight: 400;\">1,0; 1,6; 2,5<\/span><\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Vertical cylindrical cylinders for gas and air, VEE<\/strong><\/p>\n<\/td>\n<td><img loading=\"lazy\" class=\"alignnone size-full wp-image-193\" src=\"https:\/\/www.hng-ua.com\/wp-content\/uploads\/2018\/08\/34.jpg\" alt=\"\" width=\"107\" height=\"153\"><\/td>\n<td><span style=\"font-weight: 400;\">2; 4; 6,3; 10; 16; 25<\/span><\/td>\n<td>\n<ul>\n<li><span style=\"font-weight: 400;\">1,0; 1,6; 2,5<\/span><\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n\n<p class=\"has-text-align-center\"><strong><strong>Our company also has experience in manufacturing fire tanks:<\/strong><\/strong><\/p>\n\n\n\n<p><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignleft is-resized\"><img loading=\"lazy\" src=\"https:\/\/www.hng-ua.com\/wp-content\/uploads\/2020\/07\/\u0447\u0435\u0440\u0442\u0435\u0436-\u043f\u0440\u043e\u0442\u0438\u0432\u043e\u043f\u043e\u0436\u0430\u0440\u043d\u043e\u0433\u043e-\u0440\u0435\u0437\u0435\u0440\u0432\u0443\u0430\u0440\u0430.jpg\" alt=\"\" class=\"wp-image-603\" width=\"347\" height=\"530\" srcset=\"https:\/\/www.hng-ua.com\/wp-content\/uploads\/2020\/07\/\u0447\u0435\u0440\u0442\u0435\u0436-\u043f\u0440\u043e\u0442\u0438\u0432\u043e\u043f\u043e\u0436\u0430\u0440\u043d\u043e\u0433\u043e-\u0440\u0435\u0437\u0435\u0440\u0432\u0443\u0430\u0440\u0430.jpg 539w, https:\/\/www.hng-ua.com\/wp-content\/uploads\/2020\/07\/\u0447\u0435\u0440\u0442\u0435\u0436-\u043f\u0440\u043e\u0442\u0438\u0432\u043e\u043f\u043e\u0436\u0430\u0440\u043d\u043e\u0433\u043e-\u0440\u0435\u0437\u0435\u0440\u0432\u0443\u0430\u0440\u0430-196x300.jpg 196w\" sizes=\"(max-width: 347px) 100vw, 347px\" \/><\/figure><\/div>\n\n\n<p>These tanks are designed to store fire water at production facilities where flammable liquids are present.<\/p>\n\n\n\n<p>A typical fire extinguishing tank is a horizontal cylindrical tank with a neck for access to the tank and nozzles for receiving and pumping water. At the request of the customer, it is possible to additionally provide technological hatches, necks, spigots, ladders, observation platforms and various technological equipment: pump, level sensor, alarm, valves, piping, etc.<\/p>\n\n\n\n<p>To prevent deformation, the tank is reinforced inside with steel stiffeners.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><strong><strong>Technical characteristics:<\/strong><\/strong><\/p>\n\n\n\n<p>Volume V, \u043c<sup>3<\/sup>: 10\u2026100<\/p>\n\n\n\n<p>Diameter, \u043c\u043c: 2220\u20263240<\/p>\n\n\n\n<p>Length, \u043c\u043c: 3310\u202612700<\/p>\n\n\n\n<p><strong>Material:<\/strong> carbon steel, stainless steel.<\/p>\n\n\n\n<p><strong><strong>&#8220;Khimmashneftegaz&#8221; <\/strong>supplies all types of steel tanks. Here you can buy a fire tank made both according to a standard design and to order &#8211; according to individual drawings.<\/strong><\/p>\n\n\n\n<p class=\"has-text-align-center\"><strong><strong>&#8220;Khimmashneftegaz&#8221; will be glad to see you among our customers and partners.<\/strong><\/strong><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Capacitive equipment of our own production: Designing and manufacturing of tank equipment according to standard and non-standard designs is one of the main activities of the production enterprise &#8220;Khimmashneftegaz&#8221;. Capacitive equipment is designed for receiving, storing, processing and dispensing aggressive, toxic and non-toxic, explosive and non-explosive and other liquid and gaseous products for use in [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/www.hng-ua.com\/en\/wp-json\/wp\/v2\/pages\/1382"}],"collection":[{"href":"https:\/\/www.hng-ua.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.hng-ua.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.hng-ua.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hng-ua.com\/en\/wp-json\/wp\/v2\/comments?post=1382"}],"version-history":[{"count":2,"href":"https:\/\/www.hng-ua.com\/en\/wp-json\/wp\/v2\/pages\/1382\/revisions"}],"predecessor-version":[{"id":2169,"href":"https:\/\/www.hng-ua.com\/en\/wp-json\/wp\/v2\/pages\/1382\/revisions\/2169"}],"wp:attachment":[{"href":"https:\/\/www.hng-ua.com\/en\/wp-json\/wp\/v2\/media?parent=1382"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}